Handover Test Systems - Page 3

50 Handover Test Systems from 4 Manufacturers meet your specification.
Description:95 dB 8 x 1 Programmable Attenuator Assembly from 30 to 6000 MHz
Attenuation Accuracy:
±0.5 to 1.25 dB
Configuration:
8 x 1 LC Handover Test System
Type:
Limited Fan Out
AC Supply Voltage:
100 to 240 VAC @ 47-63 Hz
Attenuation:
0 to 95 dB
Input Power:
27 dBm
Insertion Loss:
26 to 32 dB
more info
Description:800 to 2700 MHz, 0 to 70 dB 2x3 Handover Test System
Attenuation Accuracy:
±0.5 dB
Configuration:
2x3
Control Interface:
Manual
Type:
Manual
Attenuation:
0 to 70 dB
Input Power:
1 W
Insertion Loss:
10.6 dB
more info
Description:800 to 2700 MHz, 0 to 70 dB 4x5 Handover Test System
Attenuation Accuracy:
±0.5 dB
Configuration:
4x5
Control Interface:
Manual
Type:
Manual
Attenuation:
0 to 70 dB
Input Power:
1 W
Insertion Loss:
18 dB
more info
Description:500 MHz to 6 GHz, 0 to 95 dB 8x2 Handover Test System
Attenuation Accuracy:
±0.5 to 1.25 dB
Configuration:
8x2
Control Interface:
Manual, Ethernet, RS-232
Type:
Limited Fan Out
AC Supply Voltage:
100-240 VAC @ 47-63 Hz
Attenuation:
0 to 95 dB
Input Power:
27 dBm
Insertion Loss:
29.9 to 31.9 dB
more info
Description:500 MHz to 6 GHz, 0 to 95 dB 16x3 Handover Test System
Attenuation Accuracy:
±0.5 to 1.25 dB
Configuration:
16x3
Control Interface:
Manual, Ethernet, RS-232
Type:
Limited Fan Out
AC Supply Voltage:
100-240 VAC @ 47-63 Hz
Attenuation:
0 to 95 dB
Input Power:
27 dBm
Insertion Loss:
29.9 to 35.5 dB
more info
Description:500 MHz to 6 GHz, 0 to 95 dB 8x16 Handover Test System
Attenuation Accuracy:
±0.5 to 1.25 dB
Configuration:
8x16
Control Interface:
Manual, Ethernet, RS-232
Type:
Full Fan Out
AC Supply Voltage:
100-240 VAC @ 47-63 Hz
Attenuation:
0 to 95 dB
Input Power:
30 to 36 dBm
Insertion Loss:
33 to 44 dB
more info
Description:30 to 3000 MHz, 0 to 95 dB 12x12 Handover Test System
Attenuation Accuracy:
±0.5 to 1.25 dB
Configuration:
12x12
Control Interface:
Manual, Ethernet, RS-232
Type:
Full Fan Out
AC Supply Voltage:
100-240 VAC @ 47-63 Hz
Attenuation:
0 to 95 dB
Input Power:
1 W
Insertion Loss:
44 to 47 dB
more info
Description:48x6 Full Fan-Out Handover Test System from 700 to 3000 MHz
Attenuation Accuracy:
±0.5 to 1.25 dB
Configuration:
48x6
Control Interface:
Manual, Ethernet, RS-232
Type:
Full Fan Out
AC Supply Voltage:
100-240 VAC @ 47-63 Hz
Attenuation:
0 to 95 dB
Input Power:
1 W
Insertion Loss:
46 to 49 dB
more info
Description:2 to 6 GHz, 0 to 95 dB 2x1 Handover Test System
Attenuation Accuracy:
±0.5 to 1.25 dB
Configuration:
2x1
Control Interface:
Manual, Ethernet, RS-232
AC Supply Voltage:
+12 Vdc (100-240 VAC AC/DC transformer included)
Attenuation:
0 to 95 dB
Input Power:
27 to 33 dBm
Insertion Loss:
12.5 dB
more info
Description:2 to 6 GHz, 0 to 63 dB 4x4 Handover Test System
Attenuation Accuracy:
±0.5 to 1.25 dB
Configuration:
4x4
Control Interface:
Manual, Ethernet, RS-232
Type:
Limited Fan Out
AC Supply Voltage:
100-240 VAC @ 47-63 Hz
Attenuation:
0 to 63 dB
Input Power:
27 to 33 dBm
Insertion Loss:
24 dB
more info
Description:2 to 6 GHz, 0 to 95 dB 8x8 Handover Test System
Attenuation Accuracy:
±0.5 to 1.25 dB
Configuration:
8x8
Control Interface:
Manual, Ethernet, RS-232
AC Supply Voltage:
100-240 VAC @ 47-63 Hz
Attenuation:
0 to 95 dB
Input Power:
27 to 33 dBm
Insertion Loss:
35 dB
more info

FiltersReset All

Configuration

Control Interface

Type

Attenuation (dB)

Apply

Input Power (W)

Apply