RF Detectors

1285 RF Detectors from 49 manufacturers listed on everything RF

RF Detectors from the leading manufacturers are listed below. Use the filters to narrow down on products based on your requirement. Download Datasheets, Compare products and Request Quotations. Your Inquiry will be directed to the manufacturer and their distributors who will get back to you with a quote.

Description:RMS Power Detector from 0.1 to 67 GHz for 5G/6G Applications
Frequency:
100 MHz to 67 GHz
Type:
Power Detector
Application:
6G, 5G, 4G, Radar, Test & Measurement
Package Type:
Module with Connectors
Connectors:
1.85 mm, 1.85 mm - Female
more info
Description:10 MHz to 8 GHz, Log Detector with -25 mV/dB slope
Frequency:
10 MHz to 8 GHz
Type:
Log Detector
Dynamic Range:
65 dB
Input Connector:
SMA
Application:
RSSI Measurements
Package Type:
Module with Connectors
Connectors:
SMA
more info
Description:10 to 200 MHz, Phase Detector with Negative Polarity
Frequency:
10 to 200 MHz
Type:
Phase Detector
Polarity:
Negative
Application:
Monitoring Circuits, Phase Locked Loops
Package Type:
Surface Mount
more info
Description:10 to 200 MHz, Phase Detector with Negative Polarity
Frequency:
10 to 200 MHz
Type:
Phase Detector
Polarity:
Negative
Application:
Monitoring Circuits, Phase Locked Loops
more info
Description:10 MHz to 8 GHz, Log Detector with -25 mV/dB slope
Frequency:
10 MHz to 8 GHz
Type:
Log Detector
Dynamic Range:
65 dB
Input Connector:
SMA
Application:
RSSI Measurements
Package Type:
Module with Connectors
Connectors:
SMA
more info
Description:10 MHz to 8 GHz, Log Detector with -25 mV/dB slope
Frequency:
10 MHz to 8 GHz
Type:
Log Detector
Dynamic Range:
60 dB
Input Connector:
SMA
Application:
RSSI Measurements
Package Type:
Module with Connectors
Connectors:
SMA
more info
Description:1 to 100 MHz, Phase Detector with Negative Polarity
Frequency:
1 to 100 MHz
Type:
Phase Detector
Polarity:
Negative
Application:
Monitoring Circuits, Phase Locked Loops
Package Type:
Surface Mount
more info
Description:300 to 650 MHz, Phase Detector with Negative Polarity
Frequency:
300 to 650 MHz
Type:
Phase Detector
Polarity:
Negative
Application:
Monitoring Circuits, Phase Locked Loops
Package Type:
Surface Mount
more info
Description:5 to 150 MHz, Phase Detector with Negative Polarity
Frequency:
5 to 150 MHz
Type:
Phase Detector
Polarity:
Negative
Application:
Monitoring Circuits, Phase Locked Loops
more info
Description:10 MHz to 8 GHz, Log Detector with -25 mV/dB slope
Frequency:
10 MHz to 8 GHz
Type:
Log Detector
Dynamic Range:
60 dB
Input Connector:
SMA
Application:
RSSI Measurements
Package Type:
Module with Connectors
Connectors:
SMA
more info

What are RF Detectors?

An RF detector monitors or samples the output of an RF system to develop a dc output voltage proportional to the power at that point. They are used to measure and control RF power in wireless systems. RF Detectors are critical for most commercial transmitters where the output power level must not exceed certain values based on the Federal Communications Commission regulations. Power detectors are used to provide feedback to the wireless systems based on which they regulate the output power.

There are two main types of detectors - logarithmic and RMS. The logarithmic detector converts the RF power into a DC voltage proportional to the log of the value. The RMS detector creates a DC output proportional to the RMS value of the signal. Based on this DC Voltage and the type of detector we can estimate the output power.

everything RF lists RF detectors from the leading manufacturers in the space. We have over 700 products from more than 30 manufacturers listed in this category. Narrow down on products based on your requirement, view product specifications, download datasheets and request quotations.