The MIL CHC from FRANKONIA is a Compact Hybrid Chamber frequency range from 9 kHz/26 MHz to 40 GHz. It is designed for military components testing according to MIL-STD 461 and DO-160 standards and has been adapted for radiated emission and immunity tests at a 1.0 m measuring distance. This chamber uses advanced, long-lasting Frankosorb® absorber lining with nano thin-film technology for long-term stability (Ferrite F006, H450, or H600 option). The absorbers are non-combustible according to DIN EN 13501-1 class A2 – s1 d0 and hardly inflammable according to DIN EN 13501-1 class B (alternative). It has an outer dimension measuring 5.33 x 4.88 x 3.00 m.