FN-U-L1F2-24107-S5XX

Block Up Converter by ETL Systems (6 more products)

Note : Your request will be directed to ETL Systems.

FN-U-L1F2-24107-S5XX Image

The FN-U-L1F2-24107-S5XX from ETL Systems is a Block Up Converter with IF frequency 950 MHz to 1950 GHz, RF/Output Frequency 12.75 to 13.75 GHz / 13.5 to 14.5 GHz, LO Frequency 12.8 GHz, P1dB 10 to 12 dBm, Output Power 10 to 12 dBm. Tags: Rack Mount. More details for FN-U-L1F2-24107-S5XX can be seen below.

Product Specifications

View similar products

Product Details

  • Part Number
    FN-U-L1F2-24107-S5XX
  • Manufacturer
    ETL Systems
  • Description
    Falcon Ku-Band Block Upconverter

General Parameters

  • Application
    Teleports & Earth Stations, Satellite Operations, Government & Defence Applications, Telemetry, Tracking & Command, High Resilience Applications
  • Indoor / Outdoor
    Indoor
  • Redundancy
    Yes
  • Band
    Dual Band
  • Input Frequency Band
    L Band
  • IF frequency
    950 MHz to 1950 GHz
  • RF/Output Band
    Ku Band
  • RF/Output Frequency
    12.75 to 13.75 GHz / 13.5 to 14.5 GHz
  • LO Frequency
    12.8 GHz
  • P1dB
    10 to 12 dBm
  • Output Power
    10 to 12 dBm
  • OIP3
    20 to 22 dBm
  • Gain Flatness
    0.3 to 1.5 dB
  • Conversion Gain
    35 dB
  • Noise Figure
    10 to 12 dB
  • Input Power
    20 dBm
  • Group delay
    2 ns
  • Image rejection
    60 dB
  • Interface
    Ethernet via RJ45, 10BaseT/100 BaseTx. TCP/IP, SNMP V3 & HTTPS & Web browser interface
  • Phase Noise
    -120 to -70 dBc/Hz
  • Spurious
    -75 to -60 dBc
  • Impedance
    50 Ohms
  • Output Power (W)
    0.01 to 0.016 W
  • Return Loss
    10 to 15 dB(Input), 14 to 18 dB(Output)
  • Dimension
    1U high x 550mm deep x 19” wide
  • Package Type
    Rack Mount
  • Connector
    SMA
  • AC Voltage
    85 to 264 Vac
  • Power Consumption
    150 W
  • Operating Temperature
    0 to 45 Degree C
  • Storage Temperature
    -20 to 75 Degree C
  • Weight
    10 Kg
  • RoHS
    Yes
  • Humidity
    20 to 90% non-condensing
  • Altitude
    10, 000 feet AMSL (Operational) 30, 000 feet AMSL (Storage)

Technical Documents