FL8060

Note : Your request will be directed to AR RF/Microwave Instrumentation.

FL8060 Image

The FL8060 from AR RF/Microwave Instrumentation is an Electric Field Probe Kit that can be used from 20 MHz to 60 GHz. It has been specifically designed for EMC radiated immunity testing in the automotive, wireless, military, and aviation industry.

The probe kit has a separable-axis field probe, capable of measuring CW, AM, and Pulsed signals. The field probe is laser-powered (over-fiber), allowing continuous operation without recharging or replacing batteries. Additionally, this provides excellent RF isolation for the control system. It has a dynamic range of more than 54 dB with a resolution of less than 0.1 dB and a field strength range from 2 to 1000 V/m.

The field probe kit contains everything needed to operate its associated Field Probe. Remote control and laser power for the Field Probe is provided by the laser probe Interface. A 20-meter fiber-optic extension cable and fiber-optic mating adapter are also provided with the kit. It has IEEE-488 (GPIB), Ethernet, USB 2.0, RS-232, and fiber-optic serial PC interfaces.

An ortho-angle mount and adapter foot are provided for ease of mounting in common orientations. When rotated about its ortho-angle mount, the probes provide an excellent isotropic response. The FL8060 is available in a chassis that measures 278 x 65 x 65 mm and requires an AC supply from 90 to 260 V at 50-60 Hz.

The export classification for this equipment is EAR99. This equipment is controlled for export in accordance with the U.S. Export Administration Regulations.

Product Specifications

View similar products

Product Details

  • Part Number
    FL8060
  • Manufacturer
    AR RF/Microwave Instrumentation
  • Description
    Laser-Powered Electric Field Probe Kit from 20 MHz to 60 GHz

General Parameters

  • Type
    Probe/Antenna
  • Field
    Electric Field
  • Frequency
    20 MHz to 60 GHz
  • Voltage
    90 to 260 V
  • Connector
    E-2000 Compact Duplex
  • Isotropic Deviation
    ±0.5 dB @ 100 MHz
  • Typical Analog Rise Time
    600 - 2400 ns (amplitude dependent)
  • Amplitude Accuracy
    +/- 0.81 to 1.1 dB
  • Current
    0.2 to 0.6 A
  • Damage Level (CW)
    1200 V/m
  • Dynamic Range
    54 dB
  • Sample Rate
    2 Msps
  • Application
    Automotive EMC, Aviation EMC, Commercial EMC, Military EMC, Wireless R&D
  • Temperature
    10 to 40 Degree C
  • Storage Temperature
    -20 to 50 Degree C
  • Dimensions
    48.3 x 4.4 x 26.9 cm (19.00 x 1.72 x 10.60 in) Without Enclosure, 50.4 x 11.6 x 30.5 cm (19.84 x 4.58 x 12.00 in) With Enclosure
  • Weight
    2.3 kg (5.0 lb) Without Enclosure, 6.8 kg (15 lb) With Enclosure
  • Note
    Measurement Type : CW, AM & Pulse, Pulse Damage Level : 6 kV/m, Axis Type : Separable X-Y-Z Axis, Field Strength Range : 2 - 1000 V/m

Technical Documents