FR-4003

Note : Your request will be directed to Narda Safety Test Solutions.

FR-4003 Image

The FR-4003 from Narda Safety Test Solutions is a EMI Receiver with Attenuation 0 to 30 dB, Dynamic Range 80 to 200 dB, Frequency 9 kHz to 30 MHz, Input Power Level 94 to 137 dBuV, Resolution 1 Hz. More details for FR-4003 can be seen below.

Product Specifications

View similar products

Product Details

  • Part Number
    FR-4003
  • Manufacturer
    Narda Safety Test Solutions
  • Description
    9 kHz to 30 MHz EMI Test Receiver

General Parameters

  • Accuracy
    1 ppm
  • Attenuation
    0 to 30 dB
  • Attenuator Step
    10 dB
  • Connectors
    N Type, N Type - Female
  • Current
    2.5 A
  • Dimensions
    600 x 1122 x 600 mm
  • Dynamic Range
    80 to 200 dB
  • EMC Standards
    CISPR 12, CISPR 16, CISPR 25, MIL-STD, DO-160
  • Frequency
    9 kHz to 30 MHz
  • IF Bandwidth
    200 Hz to 300 kHz
  • Impedance
    50 Ohms
  • Input Power Level
    94 to 137 dBuV
  • Integrated Signal Generator
    Yes
  • Measure Detection Method
    Peak, Quasi-Peak, Average, RMS, C-Average Smart Detector function
  • Measurement Accuracy
    ±0.8 dB
  • Operating Temperature
    -10 to 60 Degree C
  • Preamplifier Gain
    20 dB
  • Preselector
    9 kHz to 30 MHz
  • Resolution
    1 Hz
  • Scan Time
    0.4 to 12400 s
  • Spurious Response
    -10 dBuV
  • Storage Temperature
    -30 to 75 Degree C
  • Supply Voltage
    100 to 240 VAC
  • Weight