The CNG-EbNo Series from Maury Microwave are fully automated instruments that can set and maintain a highly accurate ratio between a user-supplied carrier and internally generated AWGN noise, over a wide range of signal power levels and frequencies. These Precision SNR Noise Generators operate at a frequency from 50 MHz to 22 GHz. They deliver a variable output power from -55 dBm to -5 dBm with an accuracy of ±0.5 dB and can measure signals and noise accurately with Gaussian Noise crest factors up to 18 dB.

The CNG-EbNo gives system, design, and test engineers in the cellular/PCS, satellite, and military communication industries a cost-effective means of obtaining higher yield through automated testing, plus increased confidence from repeatable, accurate test results.

These noise generators support carrier-to-noise (C/N), carrier-to-noise density (C/No), bit energy-to-noise density (Eb/No), carrier-to-interferer (C/I), and power meter modes. They are ideal for military communications, WCDMA, SATCOM, NASA TDRSS, CableTV, HDTV, IS-95, CDMA, TSMA, UMTS, GPRS L-band modems, Milstar, Inmarsat, Intelsat, and general-purpose applications.

The CNG-EbNo series of noise generators can be controlled via a 6.25” color TFT touchscreen display or locally via TCP/IP & GPIB interfaces. They are available in benchtop enclosures that measure 17.00 x 5.25 x 17.50 inches and have BNC (75-ohm)/N-type (50-ohm) connectors. These generators require an AC supply from 85 to 264 V and consume less than 2 A of current.

Product Specifications

View similar products

Product Details

  • Part Number
    CNG-EbNo
  • Manufacturer
    Maury Microwave
  • Description
    Precision SNR Noise Generators from 50 MHz to 22 GHz

General Parameters

  • Application
    Cellular, Military, SATCOM
  • Noise Type
    AWGN
  • Frequency
    50 Hz to 22 GHz
  • Steps
    0.1 dB
  • Output Power dBm
    -55 to 5 dBm
  • Attenuation Range
    60 dB
  • Absolute Accuracy
    +/-0.5 dB
  • C/N Ratio Accuracy
    ±0.2 dB RSS, ±0.3 dB WCU
  • Nominal gain
    ±1 dB
  • Gain resolution
    0 to -60 dB
  • Gain flatness
    ±0.2 to ±0.4 dB
  • Flatness
    ±0.3 to ±0.5 dB
  • Creast factor
    18 dB
  • Dimension
    17 x 5.25 x 17.5 in.
  • Group delay
    ±0.20 ns/40 MHz
  • Third-order intercept point
    29 dBm
  • Impedance
    50 Ohms (Above 80 MHz) & 75 Ohms (Below 800 MHz)
  • Input Power
    -55 to 21 dBm
  • Input Voltage
    85 to 264 Vac
  • Control
    Manual
  • Connector
    BNC, N Type, N Type - Female
  • Interface
    Ethernet, GPIB, RS422/423
  • Operating Temperature
    0 to 50 Degree C
  • Note
    Current Consumption: 2 A