The PIM S1L TETRA MK2 analyzers are ideal for PIM measurements in the TETRA and UHF frequency bands. They provide a PIM sensitivity of <-165dBc (<-122dBm) and variable output power of 2x 16dBm to 44 dBm, with two continuous CW carriers, fully conform to PIM standard IEC62037. With a low noise floor of <-132dBc and dynamic range of 96 dB the analyzers provide accurate measurements. The analyzers have a large 10.2" touch screen which is convenient when working in the field. Test results can be stored and reported in different file formats: PDF, BMP screen Shots or as CSV files. The analyzer comes with three USB ports, which can be utilized for entry devices (keyboard, mouse, bar-code scanner), external data storage, or wireless devices.

Product Specifications

View similar products

Product Details

  • Part Number
    PIM S1L TETRA MK2
  • Manufacturer
    AWT Global
  • Description
    PIM Analyzers for TETRA and UHF 400 MHz Bands

General Parameters

  • Type
    Bench Top
  • TX Frequeny
    385 to 430 MHz (385 to 400 MHz, 390 to 400 MHz, 420 to 430 MHz)
  • RX Frequency
    380 to 425 MHz (380 to 385 MHz, 410 to 412 MHz, 410 to 425 MHz)
  • Transmitter Freq. Accuracy
    2 ppm
  • Tx Carrier Power
    2x 43 dBm carriers
  • Transmitter Power Accuracy
    +/- 0.35 dB
  • PIM Sensitivity
    -165 dBc @ 2x 43 dBm carriers
  • Measurements
    Distance to PIM, Noise Floor, PIM over Frequency, PIM over Time, Swept PIM
  • Operating Temperature
    0 to 45 degrees C
  • Receiver Dynamic Range
    96 dB
  • Receiver Measurement Range
    -45 to -122 dBm
  • Receiver Noise Floor
    -132 dBm
  • Dimension
    504 x 398 x 276 (mm), 19.8 x 15.7 x 10.9 (inch)
  • Display
    10.2 inch Touch Screen Display
  • Weight
    28.5 kg / 30.5 kg
  • Connector
    7/16 - Female