PP1800

PIM Analyzer by AWT Global (68 more products)

Note : Your request will be directed to AWT Global.

PP1800 Image

The PP1800 from AWT Global is a PIM Analyzer with TX Frequeny 1805 to 1880 MHz, RX Frequency 1710 to 1785 MHz, Transmitter Freq. Accuracy 200 ppm, Tx Carrier Power +15 to +44 dBm (46 dBm optional), Transmitter Power Accuracy +/- 0.35 dB. Tags: Portable. More details for PP1800 can be seen below.

Product Specifications

View similar products

Product Details

  • Part Number
    PP1800
  • Manufacturer
    AWT Global
  • Description
    Portable PIM Testers

General Parameters

  • Type
    Portable
  • TX Frequeny
    1805 to 1880 MHz
  • RX Frequency
    1710 to 1785 MHz
  • Transmitter Freq. Accuracy
    200 ppm
  • Tx Carrier Power
    +15 to +44 dBm (46 dBm optional)
  • Transmitter Power Accuracy
    +/- 0.35 dB
  • PIM Sensitivity
    -172 dBc @ 2x 43 dBm carriers
  • Transmitter Reverse Pwr. Protection
    +43 dBm for 5 sec
  • Ingress Protection
    IP66 / IP20
  • Measurements
    PIM over Time, PIM over Frequency
  • AC Power
    100 to 240V 50/60 Hz
  • Operating Temperature
    -10 °C to +50 °C
  • Power Consumption
    640 Watts (VA)
  • Receiver Dynamic Range
    > 96 dB (ref: -90 dBm)
  • Receiver Max Input Power
    -10 dBm
  • Receiver Measurement Accuracy
    +/- 2 dB @ 2 x 43 dBm
  • Receiver Noise Floor
    -138 dBm (300 Hz BW)
  • Receiver Operational Input Power
    -45 dBm RMS
  • Receiver Reverse IM
    -129 dBm / -172 dBc typ.
  • Receiver Reverse Power Protection
    +43 dBm for 5 sec
  • Dimension
    457 x 305 x 500 (mm)
  • Weight
    27 kg (26 kg)
  • Features
    Measures Intermodulation products IM3, IM5 IM7, IM9, IM11 and IM13. Single Carrier Mode for system return loss measurements. Perfect for static and dynamic PIM measurements. True constant power carriers – fully compliant to PIM standard IEC62037.
  • Humidity
    90%, RH (non condensing)

Technical Documents