5407

TEM / GTEM Cells by ETS-Lindgren (3 more products)

Note : Your request will be directed to ETS-Lindgren.

5407 Image

The 5407 from ETS-Lindgren is a GTEM Test Cell for frequency ranges from DC to 20 GHz (radiation immunity (RI)) and 9 kHz to 5 GHz (radiation emission (RE)). It enables users to perform RE and RI tests in a short time compared to an OATS or a standard chamber. This test cell allows users to perform tests quickly and accurately throughout the entire product life cycle; from design qualification testing, and moving through to pre-compliance testing and production sampling. It allows typical radiation emission tests to be completed in 15 minutes, while radiation immunity tests can be completed in half the normal time.

The 5407 can handle a CW input power of 200/500 W (with optional blower), provides a shielding effectiveness of more than 80 dB, and a field uniformity of 0-6 dB. It has been characterized by documented results from TDR and VSWR tests. This GTEM cell provides an option to use manual emissions correlation software for an in-depth analysis, two AC receptacles, and an absorber material. It measures 4.0 x 2.2 x 2.1 m (outer cell) and has 7/16-DIN and N-type connectors.

Product Specifications

Product Details

  • Part Number
    5407
  • Manufacturer
    ETS-Lindgren
  • Description
    20 GHz GTEM Test Cell for Radiation Immunity and Emission Testing

General Parameters

  • Applications
    Emission & Immunity Testing
  • Configuration
    Open
  • Connectors
    7/16 DIN, N Type
  • Dimensions
    2.1 x 4 x 2.2 m
  • Door Size
    747 x 686 mm
  • Frequency
    DC to 20 GHz
  • Impedance
    50 Ohms
  • Max Input Power
    200 to 500 W
  • Septum Height
    897 mm
  • Shielding Effectiveness
    80 dB
  • Standards
    IEC 61000-4-3 ANSI C63.4
  • Test Type
    Emission, Immunity
  • Type
    GTEM Cell
  • VSWR
    1.30:1, 1.75:1
  • Weight
    500 kg