50PA-841

Handover Test System by JFW Industries (42 more products)

Note : Your request will be directed to JFW Industries.

50PA-841 Image

The 50PA-841 from JFW Industries is a 4 x 16 Handover Test System that operates from 500 to 6000 MHz. It provides an attenuation from 0 to 95 dB with a step size of 1 dB and has a switching speed of less than 4 μsec. The system is constructed as a full fan-out network, meaning there is a non-blocked RF path between each input and output RF port. It can handle an input power of 36 dBm and has an insertion loss of less than 40 dB.

JFW’s full fan-out handover test systems are a type of matrix switch that are constructed with power divider/combiners on both halves of the matrix with programmable attenuators in between. There is an individually controlled programmable attenuator on every RF path through the matrix. This type of construction allows every input signal to be available simultaneously to every output port at differently attenuated signal levels.

The handover system can be remotely controlled via Ethernet and RS232. It also has manual control which provides a 20-button keypad along with an LCD display. The 50PA-841 is available in 19-inch rack-mountable chassis with SMA or N-type (female) connectors and is suitable for cellular test systems.

Product Specifications

View similar products

Product Details

  • Part Number
    50PA-841
  • Manufacturer
    JFW Industries
  • Description
    Rack-Mountable 4x16 Fan-Out Handover Test System from 0.5 to 6 GHz

General Parameters

  • Attenuation Accuracy
    ±0.5 to 1.25 dB
  • Configuration
    4x16
  • Connector
    N Type, SMA, SMA - Female
  • Control Interface
    Manual, RS-232, Ethernet
  • Enclosure Type
    19 inch rack mount @ 10RU high
  • Impedance
    50 Ohms
  • Manual Control
    20-Button Keypad and LCD display
  • Operating Temperature
    0 to 50 Degree C
  • Package Type
    Rack Mount
  • Step
    1 dB
  • Switching Speed
    4 microseconds typical (after command is received and processed) (3 milliseconds typical processing time)
  • Type
    Full Fan Out
  • VSWR
    1.80:1
  • AC Supply Voltage
    100-240 VAC @ 47-63 Hz
  • Attenuation
    0 to 95 dB
  • Frequency
    500 MHz to 6 GHz
  • Input Power
    30 to 36 dBm
  • Insertion Loss
    30 to 40 dB
  • Isolation
    43 to 55 dB