PS1L-800

PIM Analyzer by AWT Global (68 more products)

Note : Your request will be directed to AWT Global.

PS1L-800 Image

The PS1L-800 from AWT Global is a PIM Analyzer with TX Frequeny 791 to 821 MHz, RX Frequency 832 to 862 MHz, Transmitter Freq. Accuracy 200 ppm, Tx Carrier Power +15 to +44 dBm (46 dBm optional), Transmitter Power Accuracy +/- 0.35 dB. Tags: Bench Top. More details for PS1L-800 can be seen below.

Product Specifications

View similar products

Product Details

  • Part Number
    PS1L-800
  • Manufacturer
    AWT Global
  • Description
    Laboratory PIM Analyzers – PIM S1L

General Parameters

  • Type
    Bench Top
  • TX Frequeny
    791 to 821 MHz
  • RX Frequency
    832 to 862 MHz
  • Transmitter Freq. Accuracy
    200 ppm
  • Tx Carrier Power
    +15 to +44 dBm (46 dBm optional)
  • Transmitter Power Accuracy
    +/- 0.35 dB
  • PIM Sensitivity
    -172 dBc @ 2x 43 dBm carriers
  • Transmitter Reverse Pwr. Protection
    +43 dBm for 5 sec
  • Ingress Protection
    IP20
  • Measurements
    PIM over Time, PIM over Frequency
  • AC Power
    100 to 240V 50/60 Hz
  • Operating Temperature
    0 °C to +45 °C
  • Power Consumption
    640 Watts (VA)
  • Receiver Dynamic Range
    > 96 dB (ref: -90 dBm)
  • Receiver Max Input Power
    -10 dBm
  • Receiver Measurement Accuracy
    +/- 2 dB @ 2 x 43 dBm
  • Receiver Noise Floor
    -138 dBm (300 Hz Bandwidth), -132 dBm (1200 Hz Bandwidth)
  • Receiver Operational Input Power
    -45 dBm RMS
  • Receiver Reverse IM
    -129 dBm / -172 dBc typ.
  • Receiver Reverse Power Protection
    +43 dBm for 5 sec
  • Dimension
    521 x 396 x 236 (mm)
  • Weight
    25.3 kg
  • Features
    Test Modes: Diagnostic, Analyzer with Graphs, Sweep Mode (option), Distance to PIM (option), Distance to Fault (option). Measures intermodulation products IM3, IM5 IM7, IM9, IM11 and IM13 PIM over Time Graph and Sweep Mode Maxhold feature Data recording:
  • Humidity
    85%, RH (non condensing)