EMC Immunity Test Systems - Page 2

22 EMC Immunity Test Systems from 10 Manufacturers meet your specification.
Description:Radiated Immunity System composed by: 3030-01 + EP-602 + PMM Immunity Suite software
Test Type:
Radiated Immunity
Frequency:
5 kHz to 9.25 GHz
EMC Standards:
IEC/EN 61000-4-3
Configuration:
Test Setup/Turn-key Test System
Equipments:
Signal Generator, Field Probe and Software
Field Strength:
1.5 to 1500 V/m
Signal Generator Frequency:
9 kHz to 3 GHz
Power Level Range:
-107 to +10 dBm
more info
Description:Radiation Immunity Test System from 80 MHz to 6 GHz
Test Type:
Radiated Immunity
Frequency:
80 MHz to 6 GHz
EMC Standards:
IEC 61000-4-3
Configuration:
Test Setup/Turn-key Test System
Equipments:
Power Amplifier, Signal Generator, Antenna, Spectr...
EUT Distance:
3 m
Field Strength:
10 to 18 V/m
Amplifier Frequency:
80 MHz to 6 GHz
Output Power:
75 to 250 W
Signal Generator Frequency:
80 MHz to 6 GHz
more info
Description:Radiated Immuniity EMC Test & Control Unit
Test Type:
Radiated Immunity
Frequency:
9 kHz to 6.5 GHz
Configuration:
Test Setup/Turn-key Test System
Equipments:
Power Amplifier, Signal Generator, Power Meter
Signal Generator Frequency:
9 kHz to 6.5 GHz
Power Level Range:
-100 dBm to +13 dBm
more info
Description:50 Watts Conducted Immunity System
Test Type:
Conducted Immunity
EMC Standards:
IEC/EN 61000-4-6
Configuration:
Test Setup/Turn-key Test System
Equipments:
Power Amplifier, CDN, Directional Coupler, Adapter...
Output Power:
50 W
Signal Generator Frequency:
150 kHz to 250 MHz
Power Level Range:
46.99 dBm
more info
Description:RF Radiation Immunity Test System for EMC Compliance Testing
Test Type:
Radiated Immunity
Frequency:
Generator: 9 kHz to 3 GHz, Electric Field Probe: 1...
EMC Standards:
IEC/EN 61000-4-3
Configuration:
Test Setup/Turn-key Test System
Equipments:
Signal Generator, Field Probe and Software
Field Strength:
0.14 to 140 V/m
Signal Generator Frequency:
9 kHz to 3 GHz
Power Level Range:
-107 to +10 dBm
more info
Description:EMC Immunity Test System from 10 kHz to 18 GHz
Test Type:
Radiated Immunity
Frequency:
10 kHz to 18 GHz
EMC Standards:
ISO 11451-2
Configuration:
Stand Alone / Integrated System
Equipments:
Power Amplifier, Antenna, Field Probe and Software
EUT Distance:
2 Meter
Field Strength:
100 V/m
Amplifier Frequency:
10 kHz to 18 GHz
Output Power:
250 to 12500 W
more info
Description:100 Watts Conducted Immunity System
Test Type:
Conducted Immunity
EMC Standards:
IEC/EN 61000-4-6
Configuration:
Test Setup/Turn-key Test System
Equipments:
Power Amplifier, CDN, Directional Coupler, Adapter...
Output Power:
100 W
Signal Generator Frequency:
150 kHz to 250 MHz
Power Level Range:
50 dBm
more info
Description:60 Hz to 100 KHz, Conducted Immunity Test System for MIL-STD-461
Test Type:
Conducted Immunity
Frequency:
60 Hz to 100 KHz
EMC Standards:
MIL-STD-461
Configuration:
Test Setup/Turn-key Test System
Equipments:
Power Amplifier, Signal Generator, Field Probe and...
Signal Generator Frequency:
DC to 10 MHz
more info
Description:Conducted Disturbances Test System
Test Type:
Conducted Immunity
Frequency:
10 kHz to 400 MHz
EMC Standards:
IEC/EN 61000-4-6
Configuration:
Stand Alone / Integrated System
Equipments:
Power Amplifier, Signal Generator, Voltmeter, Dire...
Amplifier Frequency:
100 kHz to 400 MHz
Output Power:
75 W
Signal Generator Frequency:
1 Hz to 1.2 GHz
more info
Description:Conducted Disturbances Test System
Test Type:
Conducted Immunity
Frequency:
10 kHz to 400 MHz
EMC Standards:
IEC/EN 61000-4-6
Configuration:
Stand Alone / Integrated System
Equipments:
Power Amplifier, Signal Generator, Voltmeter, Dire...
Amplifier Frequency:
10 kHz to 250 MHz
Output Power:
75 W
Signal Generator Frequency:
1 Hz to 1.2 GHz
more info

FiltersReset All

Test Type

Frequency

 
 
Apply

Configuration

Equipments