TITAN™ Multi-Contact Probe

Note : Your request will be directed to MPI Corporation.

TITAN™ Multi-Contact Probe Image

The TITAN™  from MPI Corporation is a Multi-Contact Probe, designed for accurate characterization of RFICs. It operates from DC to 6 GHz and features 3 to 15 contacts, which can be individually configured as either RF, logic signal, or the bypass power supply of the RFIC. This probe has a contact resistance of 45 mΩ on Al, a contact width of 20 µm, and a wide pitch range from 50 to 300 µm. It has an insertion loss of 3 dB (without cable assembly), 5 dB (with cable assembly), and a return loss of 10 dB.

MPI’s TITAN™ Probe technology offers excellent impedance matching, electrical characteristics, and unique tip visibility. The TITAN probe is quadrant (allowing corner pads) and shield environment-compatible. This probe is the shortest of its kind and enables a wide-temperature range (-40 to 150 degrees Celsius) characterization of large ICs in a shielded environment and also supports other challenging test configurations.

Product Specifications

View similar products

Product Details

  • Part Number
    TITAN™ Multi-Contact Probe
  • Manufacturer
    MPI Corporation
  • Description
    Multi-Contact Probe from DC to 6 GHz for RFIC Testing

General Parameters

  • Configuration
    GSG, GS, SGS
  • Frequency
    DC to 6 GHz
  • Pitch range
    50 to 300 µm
  • Standard pitch step
    25 µm and 50 µm
  • Insertion loss
    3 to 5 dB
  • Return loss
    10 dB
  • DC voltage
    50 V / 300 V
  • DC current
    1.2 A
  • Contact Resistance
    45 mOhm
  • Operating Temperature
    -40 to 150 Degrees C