Handover Test Systems - Page 5

50 Handover Test Systems from 4 Manufacturers meet your specification.
Description:700 MHz to 6 GHz, 0 to 95 dB Dual 8x1 Handover Test System
Attenuation Accuracy:
±0.5 to 1.25 dB
Configuration:
Dual 8x1
Control Interface:
Manual, Ethernet, RS-232
Type:
Limited Fan Out
AC Supply Voltage:
100-240 VAC @ 47-63 Hz
Attenuation:
0 to 95 dB
Input Power:
27 dBm
Insertion Loss:
25.8 to 26.6 dB
more info
Description:500 MHz to 6 GHz, 0 to 95 dB 8x8 Handover Test System
Attenuation Accuracy:
±0.5 to 1.25 dB
Configuration:
8x8
Control Interface:
Manual, Ethernet, RS-232
Type:
Full Fan Out
AC Supply Voltage:
100-240 VAC @ 47-63 Hz
Attenuation:
0 to 95 dB
Input Power:
30 dBm
Insertion Loss:
31 to 41 dB
more info
Description:20 MHz to 1 GHz, 0 to 63 dB 6x6 Handover Test System
Attenuation Accuracy:
±0.5 dB
Configuration:
6x6
Control Interface:
Manual, Ethernet, RS-232
Type:
Full Fan Out
AC Supply Voltage:
100-240 VAC @ 47-63 Hz
Attenuation:
0 to 63 dB
Input Power:
29 dBm
Insertion Loss:
28.5 to 30 dB
more info
Description:2 to 6 GHz, 0 to 95 dB 4x4 Handover Test System
Attenuation Accuracy:
±0.5 to 1.25 dB
Configuration:
4x4
Control Interface:
Manual, Ethernet, RS-232
Type:
Full Fan Out
AC Supply Voltage:
100-240 VAC @ 47-63 Hz
Attenuation:
0 to 95 dB
Input Power:
30 dBm
Insertion Loss:
28.5 to 30.5 dB
more info
Description:700 MHz to 6 GHz, 0 to 95 dB 10x2 Handover Test System
Attenuation Accuracy:
±0.5 to 1.25 dB
Configuration:
10x2
Control Interface:
Manual, Ethernet, RS-232
Type:
Full Fan Out
AC Supply Voltage:
100-240 VAC @ 47-63 Hz
Attenuation:
0 to 95 dB
Input Power:
30 dBm
Insertion Loss:
33 to 35 dB
more info
Description:100 MHz to 1 GHz, 0 to 127 dB 6x6 Handover Test System
Attenuation Accuracy:
±0.5 dB
Configuration:
6x6
Control Interface:
Manual, Ethernet, RS-232
Type:
Full Fan Out
AC Supply Voltage:
100-240 VAC @ 47-63 Hz
Attenuation:
0 to 127 dB
Input Power:
20 dBm
Insertion Loss:
28.5 to 30 dB
more info
Description:700 MHz to 6 GHz, 0 to 63 dB 2x2 Handover Test System
Attenuation Accuracy:
±0.5 to 1.25 dB
Configuration:
2x2
Control Interface:
Manual, Ethernet, RS-232
Type:
Full Fan Out
AC Supply Voltage:
100-240 VAC @ 47-63 Hz
Attenuation:
0 to 63 dB
Input Power:
26 dBm
Insertion Loss:
19 to 20 dB
more info
Description:500 MHz to 6 GHz, 0 to 95 dB 6x2 Handover Test System
Attenuation Accuracy:
±0.5 to 1.25 dB
Configuration:
6x2
Control Interface:
Manual, Ethernet, RS-232
Type:
Full Fan Out
AC Supply Voltage:
100-240 VAC @ 47-63 Hz
Attenuation:
0 to 95 dB
Input Power:
30 to 33 dBm
Insertion Loss:
31 dB
more info
Description:500 MHz to 6 GHz, 0 to 95 dB 3x8 Handover Test System
Attenuation Accuracy:
±0.5 to 1.25 dB
Configuration:
3x8
Control Interface:
Manual, Ethernet, RS-232
Type:
Full Fan Out
AC Supply Voltage:
100-240 VAC @ 47-63 Hz
Attenuation:
0 to 95 dB
Input Power:
30 to 33 dBm
Insertion Loss:
35 dB
more info
Description:Rack-Mountable 4x16 Fan-Out Handover Test System from 0.5 to 6 GHz
Attenuation Accuracy:
±0.5 to 1.25 dB
Configuration:
4x16
Control Interface:
Manual, RS-232, Ethernet
Type:
Full Fan Out
AC Supply Voltage:
100-240 VAC @ 47-63 Hz
Attenuation:
0 to 95 dB
Input Power:
30 to 36 dBm
Insertion Loss:
30 to 40 dB
more info
Description:4 x 4 Handover Test System from 698 to 3000 MHz
Attenuation Accuracy:
±0.5 to 0.8 dB
Configuration:
4x4
Control Interface:
Manual, Ethernet, RS-232
Type:
Full Fan Out
AC Supply Voltage:
100 to 240 V
Attenuation:
0 to 127 dB
Input Power:
1 W
Insertion Loss:
27 to 29 dB
more info

FiltersReset All

Configuration

Control Interface

Type

Attenuation (dB)

Apply

Input Power (W)